PSI MEMBRANE® Pro-XFR anti-fouling membrane elements are used in the comprehensive wastewater treatment of semiconductor plants, with the product water reused for production line.
Location: Wuxi City, Jiangsu Province
Water Source: A Semiconductor Plant Group
Capacity: RO Permeate Flow Rate 16,416m³/d
User: Semiconductor Industrial Park

|
Parameter |
Pressure Vessel Quantity |
Per Pressure Vessel Membrane Quantity |
نموذج الغشاء |
Total Membrane |
|
1st |
17 |
6 |
Pro-XFR-8040 |
102 |
|
2nd |
9 |
6 |
Pro-XFR-8040 |
54 |
|
TDS |
mg/L |
Around 1600 |
- |
- |
|
Turbidity |
NTU |
<5 |
- |
- |
|
F- |
mg/L |
2.5-3.5 |
- |
- |
Statistics on Chemical Cleaning Frequency of Membrane Elements from Different Brands Under Identical Pilot Conditions