Second slide
ANWENDUNGSFALL
ANWENDUNGSFALL
Anwendung von säurebeständigen Spezialmembranen des PSI TFN in Kathodenmaterialien für neue Energiebatterien

PSI MEMBRANE® Pro-Acid specialty acid-resistant membrane elements are used for material concentration in new energy cathode material plants. The concentrated brine is discharged to an evaporator, and the product water is reused as pure water for production line processes.

Überblick über das Projekt

Location: Fuquan City, Guizhou Province
Water Source: New Energy Battery Chemical Workshop
Capacity: 6000m³/d in the First Phase
User: New Energy Battery Cathode Materials Top Enterprise
Purpose: Material Concentration, Water Reuse
Commissioning Date: August 2023

Informationen zur Auslegung von Umkehrosmosesystemen

  • Influent pH: 2
  • Quantity of Membrane System: 26 Units in the Acid-resistant Membrane Workshop
  • Einführung von Membranelementen: PSI MEMBRANE® Pro-Acid
  • PSI Membranes were installed and operated simultaneously with imported membranes, demonstrating significant advantages in salt rejection, flux stability, and cleaning resistance compared to other imported acid-resistant membrane elements.

Position

Quantity of  Membrane System

Average Design Flux

Einziehungsquote

Quantity of Membrane per Unit

Dilute Water 1st

6

18LMH

65%

144

Dilute Water 2nd

4

15LMH

50%

144

Dilute Water 3rd

3

11LMH

45%

144

Concentrate Water 1st

7

15LMH

55%

144

Concentrate Water 2nd

6

8.5LMH

40%

144

Application of PSI TFN Specialty Acid-Resistant Membranes in New Energy Battery Cathode Materials
Application of PSI TFN Specialty Acid-Resistant Membranes in New Energy Battery Cathode Materials1

Schaukasten

Application of PSI TFN Specialty Acid-Resistant Membranes in New Energy Battery Cathode Materials2
Online Nachricht