{"id":4342,"date":"2025-09-25T13:39:48","date_gmt":"2025-09-25T05:39:48","guid":{"rendered":"http:\/\/puxi\/?p=4342"},"modified":"2025-10-24T16:52:52","modified_gmt":"2025-10-24T08:52:52","slug":"application-of-psi-tfn-anti-pollution-membrane-in-semiconductor-wastewater-recycling","status":"publish","type":"post","link":"https:\/\/www.psimembrane.com\/pt\/case\/application-of-psi-tfn-anti-pollution-membrane-in-semiconductor-wastewater-recycling\/","title":{"rendered":"Aplica\u00e7\u00e3o da membrana antipolui\u00e7\u00e3o PSI TFN na reciclagem de \u00e1guas residuais de semicondutores"},"content":{"rendered":"<p>PSI MEMBRANA<sup>\u00ae<\/sup> Pro-XFR anti-fouling membrane elements are used in the comprehensive wastewater treatment of semiconductor plants, with the product water reused for production line.<\/p>\n<div style=\"margin-top: 30px;\">\n<h4><strong>Descri\u00e7\u00e3o geral do projeto<\/strong><\/h4>\n<p>Location: Wuxi City, Jiangsu Province<br \/>\nWater Source: A Semiconductor Plant Group<br \/>\nCapacity: RO Permeate Flow Rate 16,416m\u00b3\/d<br \/>\nUser: Semiconductor Industrial Park<\/p>\n<\/div>\n<div style=\"margin-top: 30px;\">\n<h4>Informa\u00e7\u00f5es sobre a conce\u00e7\u00e3o do sistema de osmose inversa<\/h4>\n<ul>\n<li>Average Design Flux: 19.05 LMH<\/li>\n<li>RO System Single Unit Design Recovery Rate: 70%<\/li>\n<li>Quantity of Membrane Systems: 6 units<\/li>\n<li>Ado\u00e7\u00e3o de Elementos de Membrana: PSI MEMBRANE<sup>\u00ae<\/sup> Pro-XFR<\/li>\n<li>Advance pilot testing and compare the performance of other imported membrane elements with significant advantages in anti-pollution PSI MEMBRANE<sup>\u00ae<\/sup> Pro-XFR.<\/li>\n<\/ul>\n<\/div>\n<div style=\"margin-top: 30px;\">\n<h4><strong>System Information<\/strong><\/h4>\n<div class=\"row pt-20\">\n<div class=\"col-md-3\">\n<p style=\"margin-top: 68px;\"><img src=\"\/wp-content\/uploads\/2025\/09\/07f9c8f456bbb9ab3531.png\" title=\"Aplica\u00e7\u00e3o da membrana antipolui\u00e7\u00e3o PSI TFN na reciclagem de \u00e1guas residuais de semicondutores\" alt=\"Application of PSI TFN Anti-pollution Membrane in Semiconductor Wastewater Recycling\" \/><\/p>\n<\/div>\n<div class=\"col-md-9\">\n<div class=\"parameter\">\n<table border=\"1\" width=\"100%\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td align=\"center\" valign=\"center\" width=\"74\" height=\"35\">\n<p align=\"center\"><strong>Par\u00e2metro <\/strong><\/p>\n<\/td>\n<td align=\"center\" valign=\"center\" width=\"202\" height=\"35\">\n<p align=\"center\"><strong>Pressure Vessel Quantity<\/strong><\/p>\n<\/td>\n<td align=\"center\" valign=\"center\" width=\"177\" height=\"35\">\n<p align=\"center\"><strong>Per Pressure Vessel Membrane Quantity<\/strong><\/p>\n<\/td>\n<td align=\"center\" valign=\"center\" width=\"162\" height=\"35\">\n<p align=\"center\"><strong>Modelo de membrana<\/strong><\/p>\n<\/td>\n<td align=\"center\" valign=\"center\" width=\"139\" height=\"35\">\n<p align=\"center\"><strong>Total &nbsp;Membrane<\/strong><br \/>\n<strong>Quantidade<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td align=\"center\" valign=\"center\" width=\"74\" height=\"35\">\n<p align=\"center\">1st<\/p>\n<\/td>\n<td align=\"center\" valign=\"center\" width=\"202\" height=\"35\">\n<p align=\"center\">17<\/p>\n<\/td>\n<td align=\"center\" valign=\"center\" width=\"177\" height=\"35\">\n<p align=\"center\">6<\/p>\n<\/td>\n<td align=\"center\" valign=\"center\" width=\"162\" height=\"35\">\n<p align=\"center\">Pro-XFR-8040<\/p>\n<\/td>\n<td align=\"center\" valign=\"center\" width=\"139\" height=\"35\">\n<p align=\"center\">102<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td align=\"center\" valign=\"center\" width=\"74\" height=\"35\">\n<p align=\"center\">2nd<\/p>\n<\/td>\n<td align=\"center\" valign=\"center\" width=\"202\" height=\"35\">\n<p align=\"center\">9<\/p>\n<\/td>\n<td align=\"center\" valign=\"center\" width=\"177\" height=\"35\">\n<p align=\"center\">6<\/p>\n<\/td>\n<td align=\"center\" valign=\"center\" width=\"162\" height=\"35\">\n<p align=\"center\">Pro-XFR-8040<\/p>\n<\/td>\n<td align=\"center\" valign=\"center\" width=\"139\" height=\"35\">\n<p align=\"center\">54<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td align=\"center\" valign=\"center\" width=\"74\" height=\"35\">\n<p align=\"center\">TDS<\/p>\n<\/td>\n<td align=\"center\" valign=\"center\" width=\"202\" height=\"35\">\n<p align=\"center\">mg\/L<\/p>\n<\/td>\n<td align=\"center\" valign=\"center\" width=\"177\" height=\"35\">\n<p align=\"center\">Around 1600<\/p>\n<\/td>\n<td align=\"center\" valign=\"center\" width=\"162\" height=\"35\">\n<p align=\"center\">-<\/p>\n<\/td>\n<td align=\"center\" valign=\"center\" width=\"139\" height=\"35\">\n<p align=\"center\">-<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td align=\"center\" valign=\"center\" width=\"74\" height=\"35\">\n<p align=\"center\">Turbidity<\/p>\n<\/td>\n<td align=\"center\" valign=\"center\" width=\"202\" height=\"35\">\n<p align=\"center\">NTU<\/p>\n<\/td>\n<td align=\"center\" valign=\"center\" width=\"177\" height=\"35\">\n<p align=\"center\">\uff1c5<\/p>\n<\/td>\n<td align=\"center\" valign=\"center\" width=\"162\" height=\"35\">\n<p align=\"center\">-<\/p>\n<\/td>\n<td align=\"center\" valign=\"center\" width=\"139\" height=\"35\">\n<p align=\"center\">-<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td align=\"center\" valign=\"center\" width=\"74\" height=\"35\">\n<p align=\"center\">F-<\/p>\n<\/td>\n<td align=\"center\" valign=\"center\" width=\"202\" height=\"35\">\n<p align=\"center\">mg\/L<\/p>\n<\/td>\n<td align=\"center\" valign=\"center\" width=\"177\" height=\"35\">\n<p align=\"center\">2.5-3.5<\/p>\n<\/td>\n<td align=\"center\" valign=\"center\" width=\"162\" height=\"35\">\n<p align=\"center\">-<\/p>\n<\/td>\n<td align=\"center\" valign=\"center\" width=\"139\" height=\"35\">\n<p align=\"center\">-<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<p align=\"center\">Statistics on Chemical Cleaning Frequency of Membrane Elements from Different Brands Under Identical Pilot Conditions<\/p>\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large is-resized\"><img class=\"wp-image-4361\" src=\"\/wp-content\/uploads\/2025\/10\/0f45ae65c9d4625aad97.png\"  width=\"800\" title=\"Application of PSI TFN Anti-pollution Membrane in Semiconductor Wastewater Recycling1\" alt=\"Application of PSI TFN Anti-pollution Membrane in Semiconductor Wastewater Recycling1\" \/><\/figure>\n<\/div>\n<div style=\"margin-top: 30px;\">\n<h4>Apresenta\u00e7\u00e3o de casos<\/h4>\n<figure class=\"wp-block-image size-full\"><img class=\"wp-image-4654\" src=\"\/wp-content\/uploads\/2025\/10\/c4ca4238a0b923820dcc.jpg\" title=\"Application of PSI TFN Anti-pollution Membrane in Semiconductor Wastewater Recycling2\" alt=\"Application of PSI TFN Anti-pollution Membrane in Semiconductor Wastewater Recycling2\" \/><\/figure>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>PSI MEMBRANE\u00ae Pro-XFR anti-fouling membrane elements are used in the comprehensive wastewater treatment of semiconductor plants, with the product water reused for production line. Project Overview Location: Wuxi City, Jiangsu Province Water Source: A Semiconductor Plant Group Capacity: RO Permeate Flow Rate 16,416m\u00b3\/d User: Semiconductor Industrial Park Reverse Osmosis System Design Information Average Design Flux: [&hellip;]<\/p>","protected":false},"author":1,"featured_media":4343,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[68],"tags":[],"acf":[],"_links":{"self":[{"href":"https:\/\/www.psimembrane.com\/pt\/wp-json\/wp\/v2\/posts\/4342"}],"collection":[{"href":"https:\/\/www.psimembrane.com\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.psimembrane.com\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.psimembrane.com\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.psimembrane.com\/pt\/wp-json\/wp\/v2\/comments?post=4342"}],"version-history":[{"count":53,"href":"https:\/\/www.psimembrane.com\/pt\/wp-json\/wp\/v2\/posts\/4342\/revisions"}],"predecessor-version":[{"id":5077,"href":"https:\/\/www.psimembrane.com\/pt\/wp-json\/wp\/v2\/posts\/4342\/revisions\/5077"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.psimembrane.com\/pt\/wp-json\/wp\/v2\/media\/4343"}],"wp:attachment":[{"href":"https:\/\/www.psimembrane.com\/pt\/wp-json\/wp\/v2\/media?parent=4342"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.psimembrane.com\/pt\/wp-json\/wp\/v2\/categories?post=4342"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.psimembrane.com\/pt\/wp-json\/wp\/v2\/tags?post=4342"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}