{"id":4439,"date":"2025-09-28T14:34:41","date_gmt":"2025-09-28T06:34:41","guid":{"rendered":"http:\/\/puxi2.wangluocloud.com\/?p=4439"},"modified":"2025-10-24T09:47:34","modified_gmt":"2025-10-24T01:47:34","slug":"application-of-psi-tfn-reverse-osmosis-membranes-in-seawater-desalination-projects","status":"publish","type":"post","link":"https:\/\/www.psimembrane.com\/de\/case\/application-of-psi-tfn-reverse-osmosis-membranes-in-seawater-desalination-projects\/","title":{"rendered":"Anwendung von PSI TFN-Membranen in der petrochemischen Entschwefelungsabwasserbehandlung"},"content":{"rendered":"<div style=\"margin-top: 30px;\">\n<h3><strong>1. Erg\u00e4nzung des Rauchgassystems der Schwefelr\u00fcckgewinnungsanlage von Shenghong Refining &amp; Chemical um Anlagen zur Beseitigung von Wei\u00dfrauch durch Membranabscheidung<\/strong><\/h3>\n<h4 align=\"justify\"><strong>\u00dcberblick \u00fcber das Projekt<\/strong><\/h4>\n<div class=\"row pt-20\">\n<div class=\"col-md-6 col-sm-6\">\n<ul>\n<li>Standort: Stadt Lianyungang, Provinz Jiangsu<\/li>\n<li>Leistung: 31m\u00b3\/h<\/li>\n<li>Zweck: Zero Liquid Discharge (ZLD)<\/li>\n<\/ul>\n<\/div>\n<div class=\"col-md-6 col-sm-6\">\n<ul>\n<li>Wasserquelle: Ammoniumsulfat Verdampfungskondensat + Terti\u00e4rkreislaufwasser<\/li>\n<li>Nutzer: Raffinerieabteilung, Shenghong Refining &amp; Chemical<\/li>\n<li>Datum der Inbetriebnahme: Dezember 2022<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<div style=\"margin-top: 16px;\">\n<div class=\"row pt-20\">\n<div class=\"col-md-6 col-sm-6\">\n<h4 align=\"justify\"><strong>Informationen zum Projekt<\/strong><\/h4>\n<p>1. Terti\u00e4res Kreislaufwasser<br \/>\nDurchflussmenge: 15m\u00b3\/h<br \/>\nTemperatur: 50\u2103<br \/>\npH=3\uff5e8<br \/>\nAmmoniumsulfat- und Ammoniumbisulfat-Konzentration: 0,02-0,8% (Gew.)<\/p>\n<\/div>\n<div class=\"col-md-6 col-sm-6\">2. Verdampfung und Kristallisation von Sekund\u00e4rkondensat<br \/>\nDurchflussmenge: 16m\u00b3\/h<br \/>\nTemperatur: 50\u2103<br \/>\npH=3\uff5e8<br \/>\nAmmoniumsulfat-Gehalt: 0,005-0,2% (Gew.), mit Spuren von Ammoniak (NH\u2083), SO\u2082, Sulfit, Bisulfit, Chlorid-Ionen usw.<\/div>\n<\/div>\n<\/div>\n<div style=\"margin-top: 19px;\">\n<h4 align=\"justify\"><strong>Ergebnis des technischen Vorschlags<\/strong><\/h4>\n<p><span style=\"font-family: Wingdings; font-size: 12.0000pt;\">n<\/span> Innerhalb der Wasseraufbereitungskapazit\u00e4t von 60-150% bleibt die maximale Konzentration von Ammoniumsulfat und Ammoniumbisulfat unter 0,5% (Gew.). Die TFN-Haupteinheit erreicht eine 40-fache Konzentration, w\u00e4hrend das gesamte konzentrierte Wasser, das in den Verdampfer gelangt, in Kombination mit der Abwassereinleitung eine 20-fache Konzentration erreicht. Bei einer maximalen Zulaufkonzentration von Ammoniumsulfat und Ammoniumbisulfit von nicht mehr als 2% ist ein normaler Betrieb gew\u00e4hrleistet.<br \/>\n<span style=\"font-family: Wingdings; font-size: 12.0000pt;\">n<\/span> Die maximale Konzentration von Ammoniumsulfat im konzentrierten Wasser darf nicht weniger als 20% betragen, um den normalen Betrieb der Anlage zu gew\u00e4hrleisten.<br \/>\n<span style=\"font-family: Wingdings; font-size: 12.0000pt;\">n<\/span> Das Ger\u00e4t erf\u00fcllt die Anforderungen von 1 Jahr Wartung alle 3 Jahre und die Lebensdauer des Ger\u00e4ts betr\u00e4gt mehr als 20 Jahre.<\/p>\n<\/div>\n<div style=\"margin-top: 30px;\">\n<h4 align=\"justify\"><strong>Technischer Vorschlag Prozessablauf der Behandlung<\/strong><\/h4>\n<p align=\"justify\">\n<figure class=\"wp-block-image size-large\"><img class=\"wp-image-4675 aligncenter\" src=\"\/wp-content\/uploads\/2025\/10\/0f636e9178ea9555af78-1.png\"  width=\"800\" align=\"center\" title=\"Anwendung von PSI TFN-Membranen in der petrochemischen Entschwefelungsabwasserbehandlung\" alt=\"Application of PSI TFN Membranes in Petrochemical Desulfurization Wastewater Treatment\" \/><\/figure>\n<\/div>\n<div style=\"margin-top: 30px;\">\n<h4 align=\"justify\"><strong>Kerntechnologie &amp; Vorteile<\/strong><\/h4>\n<div>Kernst\u00fcck des Projekts ist das Membrantrennsystem PSI TFN, das sich durch folgende Eigenschaften auszeichnet:<\/div>\n<p><span style=\"font-family: Wingdings; font-size: 12.0000pt;\">n<\/span> Optimierte mehrschichtige Membranstruktur, die speziell f\u00fcr die anspruchsvolle Entfernung von Ammoniumionen in Ammoniumsulfatl\u00f6sungen entwickelt wurde und eine optimale Sulfatr\u00fcckhalteeffizienz gew\u00e4hrleistet;<br \/>\n<span style=\"font-family: Wingdings; font-size: 12.0000pt;\">n<\/span> Hohe Durchflussleistung, die eine h\u00f6here Wasserproduktion ohne Erh\u00f6hung des Betriebsdrucks erm\u00f6glicht;<br \/>\n<span style=\"font-family: Wingdings; font-size: 12.0000pt;\">n<\/span> Chemische Reinigungsbest\u00e4ndigkeit, mit einem breiten pH-Reinigungsbereich (pH 1-13), der anorganische Ablagerungen, organische Verschmutzungen und mikrobielle Verunreinigungen wirksam entfernt;<br \/>\n<span style=\"font-family: Wingdings; font-size: 12.0000pt;\">n<\/span> Vollautomatische und pr\u00e4zise Fertigungstechnologie, die ein fortschrittliches Design mit verk\u00fcrzter Membranblattl\u00e4nge und erh\u00f6hter Blattzahl beinhaltet, wodurch das Gesamtverschmutzungspotenzial reduziert und die Membranleistung maximiert wird.<\/p>\n<\/div>\n<div style=\"margin-top: 38px;\">\n<h3><strong>2. Installation einer verfahrbaren Membrantrennanlage f\u00fcr die Behandlung von Verdampfungskondensat in der Ammoniumsulfatanlage von Zhongke Refining &amp; Chemical<\/strong><\/h3>\n<p>Die speziell entwickelte Nanofiltrationsmembran NF98-SPEC-8040 hat erfolgreich importierte Membranen ersetzt und eine effiziente Trennung von Ammoniumsulfat-Abwasser in der petrochemischen Industrie erm\u00f6glicht. Sie erm\u00f6glicht die Wiederverwendung von gereinigtem Wasser und die hochkonzentrierte Anreicherung von Ammoniumsulfat-Sole.<\/p>\n<\/div>\n<div style=\"margin-top: 30px;\">\n<h4><strong>\u00dcberblick \u00fcber das Projekt<\/strong><\/h4>\n<p>Standort: Zhanjiang Stadt, Provinz Guangdong<br \/>\nWasserquelle: Ammoniumsulfat Verdunstungskondensat<br \/>\nLeistung: 20m\u00b3\/h<br \/>\nBenutzer: Raffinerieabteilung III, Zhongke Refining &amp; Chemical<br \/>\nZweck: Wiederverwendung von Verdunstungskondensatwasser<br \/>\nDatum der Inbetriebnahme: Juli 2022<\/p>\n<div style=\"margin-top: 30px;\">\n<h4><strong>Informationen zum Projekt<\/strong><\/h4>\n<p>Bei der in diesem Projekt zu behandelnden Rohfl\u00fcssigkeit handelt es sich um Ammoniumsulfat-Verdampfungskondensat aus Entschwefelungsanlagen auf Ammoniakbasis. Es weist einen hohen Ammoniumstickstoffgehalt, einen starken S\u00e4uregehalt und eine hohe Temperatur auf. Die wichtigsten Konstruktionsparameter f\u00fcr die Einspeisung in das auf einem Gestell montierte System sind in der rechten Tabelle aufgef\u00fchrt.<\/p>\n<\/div>\n<div class=\"parameter\" style=\"width: 760px; margin: 0px auto;\">\n<table border=\"1\" width=\"100%\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td colspan=\"2\" width=\"172\" height=\"35\">\n<p align=\"center\"><strong>&nbsp;<\/strong><strong>M<\/strong><strong>edium <\/strong><\/p>\n<\/td>\n<td width=\"133\" height=\"35\">\n<p align=\"center\"><strong>Verdampfungskondensat<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"127\" height=\"35\">\n<p align=\"center\">Behandlungskapazit\u00e4t<\/p>\n<\/td>\n<td valign=\"center\" width=\"45\" height=\"35\">\n<p align=\"center\">m<sup>3<\/sup>\/h<\/p>\n<\/td>\n<td valign=\"center\" width=\"133\" height=\"35\">\n<p align=\"center\">25<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"127\" height=\"35\">\n<p align=\"center\">Einlasstemperatur<\/p>\n<\/td>\n<td valign=\"center\" width=\"45\" height=\"35\">\n<p align=\"center\">\u2103<\/p>\n<\/td>\n<td valign=\"center\" width=\"133\" height=\"35\">\n<p align=\"center\">\uff1c80<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"127\" height=\"35\">\n<p align=\"center\">Betriebsdruck<\/p>\n<\/td>\n<td valign=\"center\" width=\"45\" height=\"35\">\n<p align=\"center\">MPa<\/p>\n<\/td>\n<td valign=\"center\" width=\"133\" height=\"35\">\n<p align=\"center\">\uff1c2.5<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"127\" height=\"35\">\n<p align=\"center\">pH-Wert<\/p>\n<\/td>\n<td valign=\"center\" width=\"45\" height=\"35\">\n<p align=\"center\">-<\/p>\n<\/td>\n<td valign=\"center\" width=\"133\" height=\"35\">\n<p align=\"center\">2\uff5e5<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"127\" height=\"35\">\n<p align=\"center\">Ammoniak Stickstoff<\/p>\n<\/td>\n<td valign=\"center\" width=\"45\" height=\"35\">\n<p align=\"center\">mg\/l<\/p>\n<\/td>\n<td valign=\"center\" width=\"133\" height=\"35\">\n<p align=\"center\">\uff1c2000<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"127\" height=\"35\">\n<p align=\"center\">Schwebende Feststoffe<\/p>\n<\/td>\n<td valign=\"center\" width=\"45\" height=\"35\">\n<p align=\"center\">mg\/l<\/p>\n<\/td>\n<td valign=\"center\" width=\"133\" height=\"35\">\n<p align=\"center\">\uff1c50<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"127\" height=\"35\">\n<p align=\"center\">&nbsp;Leitf\u00e4higkeit<\/p>\n<\/td>\n<td valign=\"center\" width=\"45\" height=\"35\">\n<p align=\"center\">\u03bcS\/cm<\/p>\n<\/td>\n<td valign=\"center\" width=\"133\" height=\"35\">\n<p align=\"center\">\uff1c12000<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"127\" height=\"35\">\n<p align=\"center\">Permeat-Verh\u00e4ltnis<\/p>\n<\/td>\n<td valign=\"center\" width=\"45\" height=\"35\">\n<p align=\"center\">-<\/p>\n<\/td>\n<td valign=\"center\" width=\"133\" height=\"35\">\n<p align=\"center\">80%<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"127\" height=\"35\">\n<p align=\"center\">Konzentrat-Verh\u00e4ltnis<\/p>\n<\/td>\n<td valign=\"center\" width=\"45\" height=\"35\">\n<p align=\"center\">-<\/p>\n<\/td>\n<td valign=\"center\" width=\"133\" height=\"35\">\n<p align=\"center\">20%<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" align=\"center\" width=\"172\" height=\"35\">\n<p align=\"center\">Normen f\u00fcr Rohrleitungen und Flansche<\/p>\n<\/td>\n<td width=\"133\" height=\"35\">\n<p align=\"center\">SH\/T 3405, SH\/T 3406<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table style=\"margin-top: 30px;\" border=\"1\" width=\"80%\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td width=\"77\" height=\"35\">\n<p align=\"center\"><strong>NEIN.<\/strong><\/p>\n<\/td>\n<td width=\"289\" height=\"35\">\n<p align=\"center\"><strong>Artikel<\/strong><\/p>\n<\/td>\n<td width=\"241\" height=\"35\">\n<p align=\"center\"><strong>&nbsp;<\/strong><strong>Wert<\/strong><strong>&nbsp;<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"77\" height=\"35\">\n<p align=\"center\">1<\/p>\n<\/td>\n<td width=\"289\" height=\"35\">\n<p align=\"center\">pH-Wert<\/p>\n<\/td>\n<td width=\"241\" height=\"35\">\n<p align=\"center\">6.5\uff5e9.0<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"77\" height=\"35\">\n<p align=\"center\">2<\/p>\n<\/td>\n<td width=\"289\" height=\"35\">\n<p align=\"center\">CSB, mg\/L<\/p>\n<\/td>\n<td width=\"241\" height=\"35\">\n<p align=\"center\">\uff1c60<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"77\" height=\"35\">\n<p align=\"center\">3<\/p>\n<\/td>\n<td width=\"289\" height=\"35\">\n<p align=\"center\">BSB, mg\/L<\/p>\n<\/td>\n<td width=\"241\" height=\"35\">\n<p align=\"center\">\uff1c10<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"77\" height=\"35\">\n<p align=\"center\">4<\/p>\n<\/td>\n<td width=\"289\" height=\"35\">\n<p align=\"center\">&nbsp;Ammoniak-Stickstoff, mg\/L<\/p>\n<\/td>\n<td width=\"241\" height=\"35\">\n<p align=\"center\">\uff1c10<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"77\" height=\"35\">\n<p align=\"center\">5<\/p>\n<\/td>\n<td width=\"289\" height=\"35\">\n<p align=\"center\">&nbsp;Schwebende Feststoffe (SS), mg\/L<\/p>\n<\/td>\n<td width=\"241\" height=\"35\">\n<p align=\"center\">\uff1c30<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"77\" height=\"35\">\n<p align=\"center\">6<\/p>\n<\/td>\n<td width=\"289\" height=\"35\">\n<p align=\"center\">&nbsp;Tr\u00fcbung, NTU<\/p>\n<\/td>\n<td width=\"241\" height=\"35\">\n<p align=\"center\">\uff1c10<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"77\" height=\"35\">\n<p align=\"center\">7<\/p>\n<\/td>\n<td width=\"289\" height=\"35\">\n<p align=\"center\">Sulfid-Ion, mg\/L<\/p>\n<\/td>\n<td width=\"241\" height=\"35\">\n<p align=\"center\">\uff1c0.1<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"77\" height=\"35\">\n<p align=\"center\">8<\/p>\n<\/td>\n<td width=\"289\" height=\"35\">\n<p align=\"center\">Erd\u00f6lsubstanzen, mg\/L<\/p>\n<\/td>\n<td width=\"241\" height=\"35\">\n<p align=\"center\">\uff1c2.0<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"77\" height=\"35\">\n<p align=\"center\">9<\/p>\n<\/td>\n<td width=\"289\" height=\"35\">\n<p align=\"center\">Fl\u00fcchtige Phenole, mg\/L<\/p>\n<\/td>\n<td width=\"241\" height=\"35\">\n<p align=\"center\">\uff1c0.5<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"77\" height=\"35\">\n<p align=\"center\">10<\/p>\n<\/td>\n<td width=\"289\" height=\"35\">\n<p align=\"center\">Kalziumh\u00e4rte (als CaCO\u2083), mg\/L<\/p>\n<\/td>\n<td width=\"241\" height=\"35\">\n<p align=\"center\">50-300<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"77\" height=\"35\">\n<p align=\"center\">11<\/p>\n<\/td>\n<td width=\"289\" height=\"35\">\n<p align=\"center\">Gesamtalkalit\u00e4t (als CaCO\u2083), mg\/L<\/p>\n<\/td>\n<td width=\"241\" height=\"35\">\n<p align=\"center\">50-300<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"77\" height=\"35\">\n<p align=\"center\">12<\/p>\n<\/td>\n<td width=\"289\" height=\"35\">\n<p align=\"center\">&nbsp;Chlorid-Ion, mg\/L<\/p>\n<\/td>\n<td width=\"241\" height=\"35\">\n<p align=\"center\">\uff1c30<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"77\" height=\"35\">\n<p align=\"center\">13<\/p>\n<\/td>\n<td width=\"289\" height=\"35\">\n<p align=\"center\">Sulfat-Ion, mg\/L<\/p>\n<\/td>\n<td width=\"241\" height=\"35\">\n<p align=\"center\">\uff1c50<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"77\" height=\"35\">\n<p align=\"center\">14<\/p>\n<\/td>\n<td width=\"289\" height=\"35\">\n<p align=\"center\">Eisen, mg\/L<\/p>\n<\/td>\n<td width=\"241\" height=\"35\">\n<p align=\"center\">\uff1c0.5<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"77\" height=\"35\">\n<p align=\"center\">15<\/p>\n<\/td>\n<td width=\"289\" height=\"35\">\n<p align=\"center\">Leitf\u00e4higkeit, \u03bcS\/cm<\/p>\n<\/td>\n<td width=\"241\" height=\"35\">\n<p align=\"center\">\uff1c100<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<h4><strong>Technische Ergebnisse<\/strong><\/h4>\n<div>Unter der Voraussetzung, dass das Rohwasser die Anforderungen f\u00fcr den Einlass erf\u00fcllt, muss das gereinigte Wasser dem China Petrochemical Corporation Enterprise Standard Q\/SH 0628.2-2014 f\u00fcr die Qualit\u00e4t des Zusatzwassers entsprechen. Dar\u00fcber hinaus darf der Ausgangsdruck nicht weniger als 0,6 MPa(g) betragen, und die Temperatur muss unter 40 \u00b0C liegen. Die spezifischen Indikatoren sind in der obigen Tabelle aufgef\u00fchrt.<br \/>\nInnerhalb von 60-110% des vorgesehenen Betriebsbereichs muss die Qualit\u00e4t des gereinigten Wassers dem Sinopec Q\/SH 0628.2-2014-Zusatzwasser-Standard entsprechen, mit einer R\u00fcckgewinnungsrate von nicht weniger als 80%.<\/div>\n<p><span style=\"font-family: Wingdings; font-size: 12.0000pt;\">n<\/span> Die Ger\u00e4te m\u00fcssen nur alle 4 Jahre gewartet werden und haben eine Lebensdauer von mehr als 15 Jahren.<br \/>\n<span style=\"font-family: Wingdings; font-size: 12.0000pt;\">n<\/span> Das System muss 4 Jahre lang kontinuierlich betrieben werden k\u00f6nnen. Bei Membrankl\u00e4ranlagen, die nicht im Dauerbetrieb arbeiten k\u00f6nnen, muss eine Anlage in Betrieb und eine in Bereitschaft sein.<\/p>\n<div style=\"margin-top: 30px;\">\n<h4><strong>Technischer Vorschlag Prozessablauf der Behandlung<\/strong><\/h4>\n<div class=\"wp-block-image\" style=\"margin-top: 30px;\">\n<figure class=\"aligncenter size-large\"><img class=\"alignnone wp-image-4687 size-medium\" src=\"\/wp-content\/uploads\/2025\/10\/4bad784f9d558cd9beee.png\"  width=\"800\" align=\"center\" title=\"Anwendung von PSI TFN-Membranen in der petrochemischen Entschwefelungsabwasserbehandlung1\" alt=\"Application of PSI TFN Membranes in Petrochemical Desulfurization Wastewater Treatment1\" \/><\/figure>\n<\/div>\n<\/div>\n<div style=\"margin-top: 30px;\">\n<h4><strong>Kerntechnologie &amp; Vorteile<\/strong><\/h4>\n<div>Kernst\u00fcck des Projekts ist das Membrantrennsystem PSI TFN, das sich durch folgende Eigenschaften auszeichnet:<\/div>\n<p><span style=\"font-family: Wingdings; font-size: 12.0000pt;\">n<\/span> Optimierte mehrschichtige Membranstruktur, die speziell f\u00fcr die anspruchsvolle Entfernung von Ammoniumionen in Ammoniumsulfatl\u00f6sungen entwickelt wurde und eine optimale Sulfatr\u00fcckhalteeffizienz gew\u00e4hrleistet;<br \/>\n<span style=\"font-family: Wingdings; font-size: 12.0000pt;\">n<\/span> Hohe Durchflussleistung, die eine h\u00f6here Wasserproduktion ohne Erh\u00f6hung des Betriebsdrucks erm\u00f6glicht;<br \/>\n<span style=\"font-family: Wingdings; font-size: 12.0000pt;\">n<\/span> Chemische Reinigungsbest\u00e4ndigkeit, mit einem breiten pH-Reinigungsbereich (pH 1-13), der anorganische Ablagerungen, organische Verschmutzungen und mikrobielle Verunreinigungen wirksam entfernt;<br \/>\n<span style=\"font-family: Wingdings; font-size: 12.0000pt;\">n<\/span> Vollautomatische und pr\u00e4zise Fertigungstechnologie, die ein fortschrittliches Design mit verk\u00fcrzter Membranblattl\u00e4nge und erh\u00f6hter Blattzahl beinhaltet, wodurch das Gesamtverschmutzungspotenzial reduziert und die Membraneffizienz maximiert wird<\/p>\n<\/div>\n<\/div>\n<div style=\"margin-top: 30px;\">\n<h4><strong>Schaukasten<\/strong><\/h4>\n<figure class=\"wp-block-image size-large\"><img class=\"wp-image-4675\" src=\"\/wp-content\/uploads\/2025\/10\/1679091c5a880faf6fb5-1.jpg\" title=\"Anwendung von PSI TFN-Membranen in der petrochemischen Entschwefelungsabwasserbehandlung2\" alt=\"Application of PSI TFN Membranes in Petrochemical Desulfurization Wastewater Treatment2\" \/><\/figure>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>1. Addition of White Smoke Elimination Membrane Separation Facilities to the Flue Gas System of Shenghong Refining &amp; Chemical&#8217;s Sulfur Recovery Uni Project Overview Location: Lianyungang City, Jiangsu Province Capacity: 31m\u00b3\/h Purpose:&nbsp;Zero Liquid Discharge (ZLD) Water Source:&nbsp;Ammonium Sulfate Evaporation Condensate + Tertiary Circulating Water User:&nbsp;Refining Division, Shenghong Refining &amp; Chemical Commissioning Date:&nbsp;December 2022 Project Information [&hellip;]<\/p>","protected":false},"author":1,"featured_media":4459,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[68],"tags":[],"acf":[],"_links":{"self":[{"href":"https:\/\/www.psimembrane.com\/de\/wp-json\/wp\/v2\/posts\/4439"}],"collection":[{"href":"https:\/\/www.psimembrane.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.psimembrane.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.psimembrane.com\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.psimembrane.com\/de\/wp-json\/wp\/v2\/comments?post=4439"}],"version-history":[{"count":101,"href":"https:\/\/www.psimembrane.com\/de\/wp-json\/wp\/v2\/posts\/4439\/revisions"}],"predecessor-version":[{"id":5064,"href":"https:\/\/www.psimembrane.com\/de\/wp-json\/wp\/v2\/posts\/4439\/revisions\/5064"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.psimembrane.com\/de\/wp-json\/wp\/v2\/media\/4459"}],"wp:attachment":[{"href":"https:\/\/www.psimembrane.com\/de\/wp-json\/wp\/v2\/media?parent=4439"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.psimembrane.com\/de\/wp-json\/wp\/v2\/categories?post=4439"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.psimembrane.com\/de\/wp-json\/wp\/v2\/tags?post=4439"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}